Charger Battery 15 Amp

Regular Price A$323.70 Special Price A$249.00
SKU
SP61084_SP1
CHARGER BATTERY 15 AMP FEATURES Built-in microchip charging control and monitoring system Optimally designed charging cycle designed for Lead Acid, AGM and Lithium batteries Overcharge protection, protecting the battery from damage due to overcharging Reverse polarity, short circuit, overload and high temperature protection LED indicators showing battery voltage, current and charging status SPECIFICATIONS Current Output: 15 Amp Output Voltage (Nom): 6, 12 & 24 Volt Battery Type Supported: LEAD ACID | AGM | GEL| LITHIUM Cooling Fan STAGE 1 – “DESULPHATION” In this initial start-up stage, a high frequency voltage pulse (0.5 sec) assists in “waking up” a deeply discharged battery. This method of pulse charging can also help to reduce build-up of sulphate crystals that may have formed on the battery plates during the time it was discharged. Pulse of 500ms on & 800MS off at 50% of maximum current output for 3 minutes, if the voltage of the battery is > 4 Volts, then the charger progresses to the next stage. STAGE 2 – “SOFT START” After the battery is connected, most conventional “Smart” Battery Chargers will immediately apply a high charging voltage and current output. This creates a large amount of gas and heat from the battery and when the consistency of the battery electrolyte / state of cell charge is uneven - (from time to time the consistency of the battery electrolyte can be uneven from daily use) - a full load charging characteristic can result in a period of potentially damaging overcharging. The Soft Start function eliminates this situation by starting the charging process slowly and softly, battery electrolyte and cell charge is able to even out, before receiving the main bulk charge. This significantly improves the battery charging capability and reception. STAGE 3 – “BULK” This is the main hard charging stage, where the charger will operate at the maximum rated current output, until the battery reaches a pre-set voltage determined by the battery type selection. Charging time period is determined by the capacity and charge state of the battery. STAGE 4 – “ABSORPTION” After the Bulk stage, the charger will automatically begin to reduce its current output depending on the charge acceptance of the battery, while maintaining a constant voltage (determined by the battery type selection - 14.3V GEL / 14.8V Lead Acid, AGM / 15.6V Calcium). When the current reduces to a predetermined threshold level charging will automatically halt, allowing the analysis stage to be performed. STAGE 5 - “ANALYSIS” (Testing the battery while charging) After the Absorption charging state, the battery charger will start the “Analysis” stage and will stop charging the battery for 1 minute. At this point, if the battery voltage is sensed at below 12.6V, the battery alarm and faulty battery indicators and alarm will sound. If the battery voltage is equal to or above 12.6V, the next Boost stage will start. STAGE 6 – “BOOST” After successfully analysing the battery condition, the charger will enter the Boost charge stage, which will charge at a slightly higher voltage ensuring the battery attains a 100% full charge. The current output is limited at 25% of the maximum rated charger output. When the current drops to the pre-set level or a maximum of 15 minutes is reached the charger will enter the last float charge stage. STAGE 7 – “FLOAT” When the charger has finished the Boost stage the Float stage will set its output voltage at 13.3V Gel, 13.7 Lead Acid / AGM or 13.8V Calcium when the charging current gets to <1.2A or a maximum time of 2 hours is reached then the charger will progress to the next stage. If a load is applied and the battery voltage drops to < 12.4 Volts the charger will return and restart from the Absorption stage. STAGE 8 – “MAINTAIN” This final stage regulates the fully charged battery. A small pulse charge is applied at 1Hz at a voltage of 13.3V to maintain the battery at its fully charged state and ready to be used at any time. If a load is applied to the battery and the battery voltage drops below 12.4 volts, the charger will restart from the Absorption stage.
More Information
Supplier SKUSP61084
Flat Rate23
Add Flat Rate1
Number of Package1
Package Depth1
Package Width1
Package Length1
exclusions

SP Tools items are flat rate shipping. Set at $200 for pallets, $100 for skids. All other items at $20 for the first item and $1.00 per additional items


Shipping Clause: Authority to Leave for Residential Addresses

We can only ship to residential delivery addresses with the status of Authority to Leave. This means that all orders destined for a residential area, where the recipient may not be present, will be marked for Authority to Leave. Under Authority to Leave, the delivery driver will leave the item at the delivery address if no one is available to receive it.

Please note that if the item is left under Authority to Leave and subsequently goes missing, it is NOT our responsibility. Please order at own risk. Thank you for your understanding.

Write Your Own Review
You're reviewing:Charger Battery 15 Amp
Copyright © 2024 Magento, Inc. All rights reserved.